Filter Results By:

Products

Applications

Manufacturers

Battery Chargers

Send current through a battery to store the energy.

See Also: Battery Discharge


Showing results: 136 - 147 of 147 items found.

  • Hardy Shaker

    HI-913 - Metrix

    This Hardy Shaker provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting a test easier. A test can be conducted on a vibration transducer and manually recorded. Multiple tests are not saved; for multiple tests use the HI-903 or HI-803 units. The HI-913 is used for testing from 7 to 10,000 Hz, it offers adjustable frequency and vibration levels. This provides a reference source for verifying the accuracy of vibration transducers, connectors, cabling and instruments or instrumentation systems. The HI-913 has a ruggedized suspension system that can support heavy transducers (up to 800 grams - see frequency limits in the manual). The HI-913 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.

  • Switching Power Supply ATS (SMPS ATS)

    8200 - Chroma ATE Inc.

    Chroma Power Supply Auto Test System model 8200 provides complete solution for PC ATX power supply, adapter and battery charger testing. The application oriented system structure makes it the most cost effective test equipment for initial test in power supply production line. To meet the power supply test requirements, Chroma Power Supply Auto Test System model 8200 has built in 20 ready-made test items. Users can simply enter the test conditions and test the power supply features while proceeding. With the report and management functions, Chroma Power Supply Auto Test System model 8200 is able to provide versatile tools to establish test documents and perform system administration.

  • RF One Power Meter

    COMM-connect

    The RF One Power Meter is a very versatile instrument covering both analog and digital carriers in an extremely wide frequency range from 30MHz to 6GHz. The RF One is capable of measuring forward and reflected power in the range of a few milliwatts up to 500 Watts. The internal operating system controls measurement, display and the I/Os allowing serial communication to PC, USB to memory stick and USB Serial communication. The I/O options are used to write plots to either memory sticks or to a connected PC, the I/Os can also be used to operate the instrument, giving commands and receiving data. For documentation reference the instrument has a real time clock. Multilayer menus are used to setup and control the operation of parameters. The RF One instrument is small, handy and light weight battery operated with more than 3 hours of continuous operation on the internal NiMh cells. Feature with XML data handling and application viewer is included. Accessory kit with soft carrying bag, car charger and coax adapters for standard types.

  • Wideband Digital RF Watt/VSWR Meter

    RF ONE 3029 - LBA Group, Inc

    The RF One Power Meter is a very versatile instrument covering both analog and digital carriers in an extremely wide frequency range from 30MHz to 6GHz. The RF One is capable of measuring forward and reflected power in the range of a few milliwatts up to 500 Watts. The internal operating system controls measurement, display and the I/Os allowing serial communication to PC, USB to memory stick and USB Serial communication. The I/O options are used to write plots to either memory sticks or to a connected PC, the I/Os can also be used to operate the instrument, giving commands and receiving data. For documentation reference the instrument has a real time clock. Multilayer menus are used to setup and control the operation of parameters. The RF One instrument is small, handy and light weight battery operated with more than 3 hours of continuous operation on the internal NiMh cells. Feature with XML data handling and application viewer is included. Accessory kit with soft carrying bag, car charger and coax adapters for standard types.

  • Portable Interface Unit

    1553-USB-PIU - Western Avionics Ltd.

    The 1553-USB-PIU is a Portable Interface Unit providing full MIL-STD-1553 test, simulation and bus analysis capability in a compact self-contained unit, to connect via a USB interface to suitable host systems. The unit provides support for all 1553A, 1553B, McAir and STANAG 3838 variants in a self contained battery operated unit, and is supplied with a matching power supply and battery charger unit for desk-top use. The 1553-USB-PIU supports concurrent Bus Controller (BC) and up to 31 Remote Terminals (RT) with Bus Monitor (BM). An additional stand-alone Chronological Bus Monitor (CBM) facility is also provided, with comprehensive multi-level triggering capability. Full error injection capability is provided in BC and RT modes, with full error detection in BC, RT, BM and CBM modes. The unit provides a variable amplitude dual redundant 1553 interface. 2 Mbytes of dual ported RAM are provided. The unit is supplied with "C" Driver library, together with a Windows GUI, providing a user friendly software tool for all 1553 set-ups, data management and storage.

  • Telemetry Transmitter for FM with up to 3 Bands

    LS-11-F - Lumistar Inc.

    The LS-11-F portable FM test transmitter is designed for checkout and troubleshooting of telemetry receiving systems operating with FM modulation. For applications with any of the ARTM modulations (Tier 0, Tier I, or Tier II), please refer to the LS-11-M Data Sheet. Complete ground stations including the antenna with LNA, RF down-converter, IF receiver, bit synchronizer, and PCM decommutator can be tested and bit error tests performed. The design allows secure links to be tested with an external encryptor. The Test Transmitter contains an internal PCM Data Simulator and Pseudorandom patterngenerator that operates in a BERT mode. The device provides simulated clock and data (without transmitter enabled) and accepts external data for modulating the internal transmitter. Complete setup can be achieved locally through the keypad and two-line LCD display or remotely through the USB Interface. Operational parameters include the PCM format parameter database information (frame sync patterns, wavewords, etc…), pre-modulation filter selection, transmitter carrier frequency, transmitter deviation, and output power level. Output power can be selected from approx. -60 to +5 dBm in 5 dB steps. The Test Transmitter contains a LiFePO4 Battery (Lithium Iron Phosphate), which provides higher energy density at ¼ the weight of legacy lead-acid batteries. The unit also provides an internal battery charger and will operate for up to twelve hours on battery power having received on a full charge.

  • 76kWh Lithium Battery 384V 200AHSolar Energy Storage LiFePO4 battery System

    SPVLI-76KWH - Zhejiang Sandi Electric Co., Ltd

    SANDI ESS lithium battery system is composed of lithium battery modules, BMS system, PV charge controller, AC/DC Charger, central control unit CCU, temperature detector, integrated structure and other parts; the solar panels in the system are battery storage and power for output; BMS module completes the detection and control of voltage, current, temperature, SOC, SOH and charging and discharging related parameters of power battery pack; PV controller and inverter realize bidirectional AC/DC function to meet the charging and discharging conversion demand of power battery pack; each detector is used to monitor the ambient temperature in real time to ensure the safety of the system.Features1. Standardized components, modular architecture, easy for expansion2. High energy density, small footprint, short construction period, strong environmental adaptability3. Battery module within the layered stack design, with more than 10 years of long design life4. Long Cycle Life LiFePO4 Lithium ion Battery system from 20KWH-500KWH optional5. The use of international advanced Mitsubishi IPM module and intelligent power module, with high power fast adjustment capability6. BMS battery management system with SOC automatic calibration and high current active balance function, combined with the perfect operation control and management strategies to achieve accurate and efficient management7. The combination of software and hardware protection, with alarm protection and automatic diagnostic functions, improve the protection strategy to ensure safe and efficient operation of the system8. Product communicates with the monitoring platform in real time through RS232, CAN communication interface, and reports various records in time to ensure real-time monitoring of the battery pack of the monitoring platform9. PV charge controller adopts three charging stages (buck charging, equalize charging and float charging) which can maximize the utilization of PV modules and batteries10. Colorful LCD display all module working information and statusSpecificationModel SPVLI-76.8KWHType of cell LiFePO4 (Lithium iron phosphate)Battery configuration 3.2V 200AH 120PCSRated capacity (KWH) 76.8kwhNominal capacity (AH) 200AHNominal voltage (VDC) 384VOperating voltage range (VDC) 312-438VRecommended Charge Voltage (VDC) 420VRecommended discharge cutoff voltage (VDC) 360VRecommended charge current(A) 100AMax Charge Current (A) 200ARecommended discharge current (A) 100AMax Discharge Current (A) 200ACharge temperature range 1~45℃Discharge temperature range -10~45℃Solar Charge Controller InputMaximum. Input voltage of solar array(Vdc) <750VdcBattery system voltage 384VDCMaximum power of solar array 40KWMaximum charge current(A) 100AEqualization charging voltage (Vdc) 426VEqualize charging recovery voltage (Vdc) 405.6VOver voltage disconnect voltage (Vdc) 438VOver voltage recovery (Vdc) 432VWorking temperature -20~50℃Protection level IP20Communication interface CAN2.0, BMSDisplay 5" LCD, EnglishCooling system Fan coolingWorking Altitude (m) ≤3000mReference Weight (Kg) 920KgReference size (W*D*H mm) 900*1100*1700mm

  • Portable Hand Held Load Cell Indicator

    MODEL SSI - Transducer Techniques, Inc

    The SSI is a Plug & Play Smart TEDS IEEE 1451.4 compliant portable handheld Load Cell Indicator. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SSI will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SSI can be set up by simple front panel push buttons. The SSI can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, inch pounds, etc. The SSI also has a Units key for automatic conversion of readings for load, torque and pressure. The SSI has an ultra-fast signal-sampling rate of 15,360 samples/second for true peak and/or valley testing capability. Auto-tare allows the meter to be set to zero for any input signal level. The SSI also features a USB port for data logging to a PC. You can also log data to the SSI’s internal memory storing up to 16,000 time and date stamped readings. The SSI also features 2 built-in solid-state alarm relays with LED and audible indicators. The SSI will operate up to 65 hours on a single charge or use the included battery charger for applications where the SSI is mounted permanently.

  • Modular DC Power Supply

    62000B series - Chroma ATE Inc.

    Chroma's new 62000B series of Modular DC Power Supplies offer many unique features for Burn-in and plating/electrolysis applications. The features include a N+1 redundancy, high power densities, hot-swappable maintenance, remote ON/OFF and programmable control via the CAN bus. The 62000B family offers 5 types of power module with ranging from 1V to 150V, current from 10A to 90A, and offers two mainframe type of six and three position. The six position mainframe can envelop in up to six power modules paralleled operation for 9KW power output. The 62000B can easily parallel up to fourteen mainframe to 120KW with current sharing and CAN bus control for bulk power applications. The Modular DC Power Supplies of 62000B are very cost effective with high power density and low current ripple. These instruments have be designed for burn-in applications such as the LCD panels, DC-DC converters, power inverters, notebook computers, battery chargers and many other types of electronic devices.

  • Programmable DC Electronic Load - (Economical)

    63200E Series - Chroma ATE Inc.

    The 63200E series are high power DC loads that include a choice of three operating voltages, 150V, 600V and 1,200V, with power levels from 2kW to 24kW and up to 2,000A in a single unit. Power levels can increase up to 240kW when multiple units are paralleled.These high power loads are designed for testing a wide range of EV products including DC charging stations, car battery discharge, on board charger power components, and other power electronics components. With its high power capabilities, parallel control and dynamic synchronization functions make this load ideal for automotive batteries, fuel cells and more. The 63200E load's master/slave control application enables units with the samevoltage specification to be used in parallel and synchronized dynamically to meet the power testing requirements. In addition, a 255-set data storage function has been built-in for recall of the stored settings at any time. When used in automated testing, the save and recall functions can save a great deal of time.

  • SWR True Antenna Analyzer

    COMM-connect

    SWR True Antenna Analyzer is a versatile analyzer covering all major communication bands from 30MHz to 2700MHz. The SWR True will analyze antennas and cables. Measurements are represented graphically as VSWR or Return Loss plots. The built in PLL synthesized generator offers a superior accuracy with small step size. The internal operating system controls measurement, display and the I/Os allowing serial communication to PC, USB to memory stick and USB Serial communication. The I/O options are used to write plots to either memory sticks or to a connected PC, the I/Os can also be used to operate the instrument, giving commands and receiving data. For documentation reference the instrument has a real time clock. Multilayer menus are used to setup and control the operation of parameters. The SWR True instrument is small, handy and light weight battery operated with more than 6 hours of continuous operation on the internal NiMh cells. Feature with XML data handling and application viewer is included. Accessory kit with soft carrying bag, car charger and coax adapters for standard types.

  • Hardy Shaker

    HI-903 - Metrix

    This is our top of the line Hardy Shaker. It provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting vibration tests easier. Tests can be conducted on multiple vibration transducers, and then the saved data can be transferred via USB Flash Drive to be displayed in an automated and customizable report using an Excel template on your computer. In manual mode, the vibration test level and test frequency can be set from 7 Hz to 10,000 Hz. The high accuracy instrument can display the vibration level in terms of g’s peak, velocity peak (in/sec or mm/s) or displacement peak-to-peak (mils or µm). The unit can support payloads up to 800 grams (see frequency limits in the manual). A built-in display reads the output sensitivity, which can be stored in memory. Complete testing sequences and data can be stored in memory for each tested sensor, the unit logs the data on the spot or stores it for later use. For testing of heavy transducers or at high frequencies, the HI-903 automatically corrects the sensitivity calculation for the effects of transducer mass loading. A built-in self-test program checks for accuracy of all calculations. The HI-903 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.